CSD2-L is our Industrial LoRaWAN Operated Low Power Conductivity and Salinity Sensor. It is designed to work in harsh environments and provide accurate measurements. Find out more at Ellenex.
Sensor
● Measure ranges conductivity:
0- 200 μS/cm, 0- 2,000 μS/cm, 0- 20 mS/cm, 0- 200 mS/cm
● Accuracy: ±1 (typ.) %FS (For more than 100 mS/cm appropriate buffer solution is
required)
● Resolution: 0.01-1 according to range mm
● Measurement range salinity: 5-60 g/Kg
● Measurement range TDS-KCI: 0-133,000 ppm
● Temperature compensation: NTC
● Storage Temperature: -10 to +60 °C
● Operation Temperature: 0 to +50 °C
Power
Physical Specification
● Materials: Sensor Head: PVC, DELRIN, stainless steel
Enclosure: POM
● Max. Pressure on Sensor Head: 5bar
● Weight: ~900 (for 3m cable) g
• Protection Rate: IP66 and UV protected enclosure and IP68 sensor head
Communication
LoRaWAN® Version, Class: 1.0.2revB, Class A (Class C on request)
LoRaWAN® Frequency Zone: AS923, EU868, US902-928, AU915-928 (other zones available on request)
LoRaWAN® Activation Type: OTA (default), ABP
Sampling Type: Periodic (default), Event triggered
Sampling Period: Configurable via downlink (default 4 hours)
Transmission Type: Per sample (default), Event triggered, Conditional
Parameter Configuration: Over-the-air via LoRaWAN® downlinks, Locally via wireless connectivity
Firmware Update: Locally via Wireless Connectivity, Over The Air
ISDN » W-Lan
Environment » Temperature Range » Industrial (-25°C / +65°C)