by Ellenex
LoRaWAN Operated Low Power Differential Pressure Transmitter With Built-in Temperature Sensor for Pressure and Flow Measurement of Gas Media
PDT2-L is our LoRaWAN Operated Low Power Differential Pressure Transmitter With Built-in Temperature Sensor for Pressure and Flow Measurement of Gas Media. It is designed to work in harsh environments and provide accurate measurements. Find out more at Ellenex.
Sensor
Range: Standard Range: ±500 Pa
(or other ranges on request)
Accuracy: ±0.2 (typ.) %Span
(combined linearity, hysteresis, repeatability)
Resolution: ±0.02 %Span
Pressure Reference: Bi-directional Differential
Temperature Coefficient of Zero: ≤±0.05 %FS/°C
Temperature Coefficient of Span: ≤±0.05 %FS/°C
Long Term Stability (1 year): ≤ ±0.05 Pa
Pressure Overload: 100 %FS
Pressure Cycles (Zero to Full Scale): 10+ Million
Compensated Temperature: -20 ~ +85°C
Power
Power Supply: Built-in Replaceable Lithium Battery, External Power (option)
Rated Voltage: 3.6 V
Battery Lifetime: 100,000+ readings and 20,000+ transmission
(With UDP protocol/ More than 10 years for most applications)
Physical Specification
Media compatibility: Air, Inert Gas
Process Connection: NPT1/8” Female (or others on request)
Weight: 450 g
Protection Rate: IP66, UV Protected
Communication
LoRaWAN® Version, Class: 1.0.2revB, Class A (Class C on request)
LoRaWAN® Frequency Zone: AS923, EU868, US902-928, AU915-928 (other zones available on request)
LoRaWAN® Activation Type: OTA (default), ABP
Sampling Type: Periodic (default), Event triggered
Sampling Period: Configurable via downlink (default 4 hours)
Transmission Type: Per sample (default), Event triggered, Conditional
Parameter Configuration: Over-the-air via LoRaWAN® downlinks, Locally via wireless connectivity
Firmware Update: Locally via Wireless Connectivity, Over The Air
ISDN » W-Lan